RH and TEMPERATURE TRANSMITTERS

Status Instruments offers In-Transit Hygienic Temperature Data Loggers

To Download Literature Click On The Model Numbers

  Model SEM160i Model SEM161
Single Channel
Output
Model SEM162
Dual Channel
Output
Single
Channel
Dual
Channel
...RELATIVE HUMIDITY
.RH Range: 0 to 100% RH 0 to 100% RH
.Temperature Range: -22 to 212F -22 to 212F
.Accuracy: 3% 2%
.Output: 4 to 20 mA
0 to 100% RH
4 to 20 mA
0 to 100% RH
...TEMPERATURE
.Sensor:

10K  NTC Thermistor
(directly read by user)

Pt100

.Accuracy: 0.9F (Between -4 to 176F) 0.7F
.Output: 4 to 20 mA (-22 to 212F) 4 to 20 mA (-22 to 212F)
...OUTPUTS
.Outputs Available:

Humidity (transmitted signal)
Temperature (directly thermistor)

Humidity, Temperature, Dew Point
Δ Temperature (Ambient - Dew Point)

.Output Type: 2-Wire Current Loop (4 to 20 mA) 2-Wire Current Loop (4 to 20 mA)
.Humidity Range: 0 to 100% RH 0 to 100% RH
.Temperature Range: -22 to 212F -22 to 212F
.Dew Point Range: 32 to 122F -22 to 212F
.Tamb - Tdew point: 32 to 122F 32 to 122F
.Output Connection: Two Connection Screw Terminal Two Connection Screw Terminal
.Maximum Output: 20.5 mA (in high burnout condition) 20.5 mA (in high burnout condition)
.Minimum Output: 3.9 mA (in low burnout condition) 3.9 mA (in low burnout condition)
.Accuracy:  (mA output / 2000)
or 5 A (whichever is the greater)
(mA output / 2000)
or 5 A (whichever is the greater)
.Loop Voltage Effect: 0.2 A / A 0.2 A / A
.Thermal Drift: 1 A / C 1 A / C
.Maximum Output Load: [(Vsupply - 10)/20] K Ohms
(Example: 700 Ohms @ 24V)
[(Vsupply - 10)/20] K Ohms
(Example: 700 Ohms @ 24V)
...DISPLAY OPTION
.Type: None 4 Digit (9 mm) Red LED
.Variables Displayed: RH, Dew Point and Temperature
.Resolution: 0.1% - 0.1 F/C
.Update Rate: 800 ms
...PROBE
.Ambient Operating Range: -31 to +221F -22 to +212F
.Ambient Humidity Range: 0 to 100% RH 0 to 100% RH
...TRANSMITTER
.Ambient Operating Range: -31 to +185F -22 to +185F
.Ambient StorageTemperature: -58 to +194F -58 to +194F
.Ambient Humidity Range: 0 to 90% RH non condensing 0 to 90% RH non condensing
...GENERAL SPECIFICATIONS
.Update Time: 3 Seconds 3 Seconds
.Start Up Time: 10 Seconds
(I out <4mA during Start Up)
10 Seconds
(I out <4mA during Start Up)
.Power Supply: 10 to 30VDC 10 to 30VDC
...DOWNLOADS
.Literature LIT LIT
.Instruction Manual IM IM

 