RH and TEMPERATURE TRANSMITTERS
| Status Instruments offers In-Transit Hygienic Temperature Data Loggers |
To Download Literature Click On The Model Numbers
|
Model SEM161 Single Channel Output |
Model SEM162 Dual Channel Output |
Model SEM165 High Temperature RH Probe |
|||
| ...RELATIVE HUMIDITY | ...RELATIVE HUMIDITY | ||||
| .RH Range: | 0 to 100% RH | .RH Range: |
0 to 100% RH Wettable |
||
| .Temperature Range: | -22 to 212ºF | ||||
| .Update Time: | 3 Seconds | .Temperature Range: |
-22ºF to +284ºF (-30ºC to 140ºC) |
||
| .Start Up Time: |
10 Seconds (I out <4mA during Start Up) |
||||
|
.Response
Time: .(Step Change T90) |
<10 seconds | ||||
| .Accuracy: | ±2% | .Accuracy: | ± 2% RH | ||
| .Output: |
4 to 20 mA 0 to 100% RH |
.Hysteresis: | <1% | ||
| .Linearity: | ± 2.5% | ||||
| ...TEMPERATURE | ... | (11 to 90% RH) | |||
| .Sensor: |
Pt100 |
.Pressure: | 400 psi Max. | ||
| .Accuracy: | ±0.7ºF | .Output: |
4 to 20 mA 0 to 100% RH |
||
| .Output: | 4 to 20 mA (-22 to 212ºF) | ||||
| ...OUTPUTS | ...TEMPERATURE | ||||
| .Outputs Available: |
Humidity, Temperature, Dew Point |
.Sensor: |
Pt100 |
||
| .Accuracy: |
± 1.8ºF |
||||
| .Number of Outputs: | 1 | 2 | .Output: | 4 to 20mA (32 to 212ºF) | |
| .Output Type: | 2-Wire Current Loop (4 to 20 mA) | ...GENERAL - HEAD ELECTRONICS | |||
| .Humidity Range: | 0 to 100% RH | .Ambient Operating Range: |
-4ºF to 131ºF |
||
| .Temperature Range: | -22 to 212ºF | ||||
| .Dew Point Range: | -22 to 212ºF | ||||
| .Tamb - Tdew point: | 32 to 122ºF | .Supply Voltage | 12 to 32 VDC | ||
| .Output Connection: | Two Connection Screw Terminal | .Load | (Vs-12) /20 = K ohms | ||
| .Maximum Output: | 20.5 mA (in high burnout condition) | ...APPROVALS | |||
| .Minimum Output: | 3.9 mA (in low burnout condition) | .Emmissions | BS EN 61326 | ||
| .Accuracy: | (mA output / 2000) or 5 µA | ...DOWNLOADS | |||
| .. | (whichever is the greater) | .Literature | LIT | ||
| .Loop Voltage Effect: | 0.2 µA / A | .Instruction Manual | IM | ||
| .Thermal Drift: | 1 µA / ºC | ||||
| .Maximum Output Load: |
[(Vsupply - 10)/20] K Ohms (Example: 700 Ohms @ 24V) |
||||
| .Channel Isolation: | 500 VDC | ||||
| ...DISPLAY OPTION | |||||
| .Type: | 4 Digit (9 mm) Red LED | ||||
| .Variables Displayed: | RH, Dew Point and Temperature | ||||
| .Resolution: | 0.1% - 0.1 ºF/ºC | ||||
| .Update Rate: | 800 ms | ||||
| ...PROBE | |||||
| .Ambient Operating Range: | -22 to +212ºF | ||||
| .Ambient Humidity Range: | 0 to 100% RH | ||||
| ...TRANSMITTER | |||||
| .Ambient Operating Range: | -22 to +185ºF | ||||
| .Ambient StorageTemperature: | -58 to +194ºF | ||||
| .Ambient Humidity Range: | 0 to 90% RH non condensing | ||||
| ...DOWNLOADS | |||||
| .Literature | LIT | ||||
| .Instruction Manual | IM | ||||